ESPAÑOL


Updated:
November 2005


 17   ELECTRIC HOOTER, 10 A.      RF-10

TWILIGHT electric hooter for AUTOMATIC control of lighting, turning on lights at nightfall and turning them off at dawn. HIGH SENSITIVITY, this electric hooter works between 15 ± 5 and 35 ± 5 Lux. ROTATING through 270°. DELAY against flashings ~ 5 s. With a short-circuit FUSE. PROTECTED against surcharges. CONTINUOUS service. SILVER contacts and PLASTIC box for OUTDOOR mounting.

Proteccion symbols (as UNE 20-3248 norm)

ELECTRIC HOOTER, 10 A.       RF-10 ELECTRIC HOOTER, 10 A.       RF-10 ELECTRIC HOOTER, 10 A.       RF-10ELECTRIC HOOTER, 10 A.       RF-10

TYPE OF POWER D.C.= A.C. 50 or 60 Hz
VOLTAGE, v.6 12 24 12 24 48 100 110 115 120 125 127 220 230 240
CURRENT, A. 0.016 0.016 0.016 0.016 0.016 0.016 0.009 0.009 0.008
PROTECTION IP 64 Outdoor mounting

       ON STOCK            UNDER MINIMUM ORDER OF 100 UNITS           NOT MADE


LOADING: NOMINAL POWER 10 amp.
INCANDESCENCE 1.500 w.
FLUORESCENCE 600 w.
SENSIBILITY: it turns on at 15 ± 5 lux, off at 35 ± 5 lux.
FIXING: on a WALL or PILLAR.
DIMENSIONS: 54 x 120 x 60 mm 200 gm.

REFERENCE
ELECTRIC HOOTER, 10 A.      RF-10


 18   ELECTRIC HOOTER WITH TIMER      CDS-24

ELECTRIC HOOTER switch + TIMING DEVICE for AUTOMATIC control of lighting, with better consumption saving, turning on light at nightfall and turning them off as the stablished time in the electric hooter elapsed.

Proteccion symbols (as UNE 20-3248 norm)

ELECTRIC HOOTER WITH TIMER        CDS-24 ELECTRIC HOOTER WITH TIMER        CDS-24 ELECTRIC HOOTER WITH TIMER        CDS-24ELECTRIC HOOTER WITH TIMER        CDS-24

TYPE OF POWER D.C.= A.C. 50 or 60 Hz
VOLTAGE, v.6 12 24 12 24 48 100 110 115 120 125 127 220/240
CURRENT, A. 0.03
PROTECTION IP 64 Outdoor mounting

       ON STOCK            UNDER MINIMUM ORDER OF 100 UNITS           NOT MADE


ROTATION: 360º in VERTICAL POSITION.
MAXIMUM LOADING: 1500 w with incandescence bulbs.
600 w with fluorescence bulbs.
SENSIVILITY: ADJUSTABLE among 5 and 300 lux.
DELAY AGAINST FLASHES: 60 seconds.
LIGHTING TIME: ADJUSTABLE from 1 h till 8 h.
STATUS INDICATOR: by a LED light.
TEMPERATURE LIMIT: TEMPERATURE LIMIT.
DIMENSIONS: 74 x 95 x 49 mm 152gm.

REFERENCE
ELECTRIC HOOTER WITH TIMER      CDS-24


 19   ELECTRIC HOOTER      DM-10

Electric hooter for AUTOMATIC control of lighting, in PASSING or SHORT STAYING areas. ELECTRIC HOOTER: -POWERFUL (RELAY of 10a). -OUTDOOR SURFACE MOUNTING. -ROTATING THROUGH 180° -3 CABLE CONECTIONS

Proteccion symbols (as UNE 20-3248 norm)

ELECTRIC HOOTER        DM-10 ELECTRIC HOOTER        DM-10 ELECTRIC HOOTER        DM-10ELECTRIC HOOTER        DM-10

TYPE OF POWER D.C.= A.C. 50 or 60 Hz
VOLTAGE, v.6 12 24 12 24 48 100 110 115 120 125 127 220/240
CURRENT, A. 0.0045
PROTECTION IP 64 Outdoor mounting

       ON STOCK            UNDER MINIMUM ORDER OF 100 UNITS           NOT MADE


LOADING: by a 10 amp RELAY.
INCANDESCENCE from 0 to 2000 w.
HALOGEN from 0 to 600 w.
3 POSITIONS: METER, TIME and LUX.
RANGE: 12 m at 110° (ROTATING).
FIXING: OUTDOOR SURFACE MOUNTING.
DIMENSIONS: 96 x 90 x 110 mm 260 gm.

REFERENCE
ELECTRIC HOOTER      DM-10


 20   ELECTRIC HOOTER      DME-3

Electric hooter for AUTOMATIC control of lighting, in PASSING or SHORT STAYING areas. -SURFACE or PANEL MOUNTING in a standard box. ELECTRIC HOOTER: -OUTPUT to TRIAC. -DETECTION of 195º - with a SWITCH, manual control. -2 CABLE SERIAL CONECTIONS

Proteccion symbols (as UNE 20-3248 norm)

ELECTRIC HOOTER       DME-3 ELECTRIC HOOTER       DME-3  ELECTRIC HOOTER       DME-3

TYPE OF POWER D.C.= A.C. 50 or 60 Hz
VOLTAGE, v.6 12 24 12 24 48 100 110 115 120 125 127 220/240
CURRENT, A. 0.0045
PROTECTION IP 64 Outdoor mounting

       ON STOCK            UNDER MINIMUM ORDER OF 100 UNITS           NOT MADE


LOADING: by TRIAC.
INCANDESCENCE from 40 to 400 w.
HALOGEN from 40 to 150 w.
3 POSITIONS: METER, TIME and LUX.
RANGE: 6 m at 195º.
FIXING: SURFACE or PANEL mounting.
DIMENSIONS: 80 x 80 x 74 mm 200 gm.

REFERENCE
ELECTRIC HOOTER      DME-3


 21   ELECTRIC HOOTER OF 5 amp,      CM-5

It is a POWERFUL electric hooter consisting in 2 parts, one magnetic field and the other mechanical. It works by a magnetic without touching both pieces. CONTINUOUS service.This Electric hooter has SILVER contacts, STAINLESS STEEL spring, in ABS white box. (Other colours by order)

Proteccion symbols (as UNE 20-3248 norm)

ELECTRIC HOOTER OF 5 amp,        CM-5     


MATERIAL: OCd SILVER.
MAXIMUM TENSION: 60 v = and 250 v ~.
NOMINAL INTENSITY: 5 amp.
NOMINAL POWER: 150 w and 1250 v.a.
GAP: 5 mm for excitation and more than 10 mm for recovery.
MECHANIC TIMELIFE: over 10 million movements.
FIXING: SURFACE mounting.
MAGNET DIMENS.: 64 x 12 x 14,5 mm 23 gm.
MECANISM DIMENS.: 64 x 17 x 14,5 mm 19 gm.

REFERENCE
ELECTRIC HOOTER OF 5 amp,      CM-5



INFORMATION HOME CONTACT US